Polymer housing made of anthracite PC with lamp cover in opal PC or with pictogram corresponding to DIN 4844 for indication luminaires
 
Illuminant: 2W 36 LED
 
Emergency operation using electronic emergency lighting unit including charging, control display, mains monitoring and protection against total discharge
 
Mains operation via electronic ballast. Automatic self-test application
 
1 cable entry point with silicone/synthetic rubber grommet, non-ageing, form-retaining
 
Mounting via 2 sealed boreholes on the rear of the luminaire
 
 
 

 

Coburg II
 
Protection rating IP65, protection class II
 
Plastic luminaire made of glass fibre reinforced polyester, single or twin-lamp
 
With protecting tube reflector or square-edged lamp cover made of PC (shatter-proof), with internal mirror surface wide beam, extremely wide beam or narrow beam
 
Emergency operation using electronic emergency lighting unit including charging, control display, mains monitoring and protection against total discharge
 
Mains operation via electronic ballast. Automatic self-test application
 
Ready to be connected using 2 M20 cable entry points
 
2 stainless steel mounting clips for variable mounting distance
 
 
 
 

Passau II
 
Passau II emergency light supply unit with Kiruna or Tegel models
 
Protection rating IP44, protection class II
 
Emergency lighting for luminaires complying with protection classes I and II with electronic ballast
 
Housing made of plastic (protection class II)
 
Electronic supply unit with transducer for emergency operation with DC current
 
Automatic battery-circuit check with LED
 
Protection against total discharge
 
Maintenance-free lead battery
 
Emergency lighting period of 1 hour or 3 hours with self-test
 
Permissible ambient temperature -5°C up to + 40°C
 
 
 

Tegel
 
Housing in anthracite PC and lamp cover in opal PC with pictogram corresponding to DIN 4844 for indication luminaires
 
4 LEDs of 1.2 W
 
Built-in electronic transformer (220-240V, 0/50/60 Hz)
 
1 cable entry point with silicone/synthetic rubber grommet, non-ageing, form-retaining
 
Mounting: Two sealed boreholes on the rear
 
 
 

Tempelhof
 
  • Rohrleuchte Ø 90 mm mit Piktogramm-Folie in drei verschiedenen Motiven gemäß DIN 4844 für Hinweisleuchten. Erkennungsweite der Piktogramme beträgt 16 m
  • Wand- oder Deckenmontage erfolgt über zwei Befestigungsschellen aus Edelstahl. Insgesamt sind 36 LED mit einer Gesamtleistung von 2 W verbaut
  • Netzbetrieb über integriertes, elektronisches Netzteil mit einer Versorgungsspannung von 220-240 V, 50-60 Hz
  • Im Notbetrieb kommt ein vollelektronischer Notlichteinsatz einschließlich Kontrollanzeige, Netzüberwachung und Tiefentladeschutz zum Einsatz, der für eine wahlweise Notlichtdauer von einer oder drei Stunden den vollen Lichtstrom garantiert 
 
 

Contact    Minimize
LKD Licht Kommunal Digital GmbH
 
Schmiedingerstraße 30
A-5020 Salzburg

Tel.: +43/662/432514-0
Fax: +43/662/432514-111
office@lkd.at
 

In the spotlight    Minimize
 
 
Bitburg
 
Luminaires with IP 69K ingress protection:
Resistant to the most extreme conditions, compliant with the International Food Standards (IFS).